High Capacity Stainless Steel Vertical Laboratory Drying Oven for Industrial Samples

Product Details
After-sales Service: Support Technology Online
Warranty: 1 Year
Application: Industry, School, Hospital, Lab
Gold Member Since 2025

Suppliers with verified business licenses

Registered Capital
1000000 RMB
Plant Area
10000 square meters
  • High Capacity Stainless Steel Vertical Laboratory Drying Oven for Industrial Samples
  • High Capacity Stainless Steel Vertical Laboratory Drying Oven for Industrial Samples
  • High Capacity Stainless Steel Vertical Laboratory Drying Oven for Industrial Samples
  • High Capacity Stainless Steel Vertical Laboratory Drying Oven for Industrial Samples
  • High Capacity Stainless Steel Vertical Laboratory Drying Oven for Industrial Samples
  • High Capacity Stainless Steel Vertical Laboratory Drying Oven for Industrial Samples
Find Similar Products
  • Overview
  • Product Description
  • Specification
  • FAQ
Overview

Basic Info.

Model NO.
LN-6012
Customized
Customized
Certification
CE
Structure
Desktop and Upright
Material
Aluminium, Alloy, Stainless Steel, Glass
Operational Method
Time Control
Type
Atmospheric Dryer
Temperature Measurement Accuracy
±1ºC
Timing Range
1-9999min
Transport Package
Carton Packaging
Specification
Different models have different specifications
Trademark
LN
Origin
Xinxiang, China
HS Code
7612909000
Production Capacity
5000pieces/Year

Product Description

Product Description
High Capacity Stainless Steel Vertical Laboratory Drying Oven for Industrial Samples
High Capacity Stainless Steel Vertical Laboratory Drying Oven for Industrial Samples
Desktop drying oven
Vertical drying oven
This laboratory dryer offers vertical and benchtop models, catering to diverse lab space and workflow needs.  Both series come in multiple sizes, with customizable options to fit unique requirements.
Core Features
Dual Model Options: Vertical units maximize vertical space for large-volume drying, while benchtop designs save bench space—ideal for compact labs.
Precise Temperature Control: Ranging from RT+5℃ to 250℃ (with a 300℃ limit), the intelligent digital display ensures ±0.1℃ (vertical) or ±1℃ (benchtop) accuracy.
Efficient Drying: Built-in blower circulation enables rapid, uniform heating.  Adjustable exhaust holes and double-pane glass windows allow process monitoring.
Flexible Sizing: From 16L to 1000L capacities, choose the right chamber size.  Both models include adjustable shelves (2 standard) for versatile sample placement.
Customization & Specifications
Materials (galvanized or stainless steel inner tanks) and electrical specs (220V/380V) are customizable.  Power ranges from 500W to 6000W, with timer settings (1–9999min) for automated runs.
Whether drying Chinese herbal medicines, glassware, or industrial components, these dryers deliver reliability and precision. 
Specification
Vertical drying oven
Model
101-0AS
101-00AS
101-1AS
101-2AS
101-3AS
101-4AS
101-5AS
101-0BS
101-00BS
101-1BS
101-2BS
101-3BS
101-4BS
101-5BS
(A is a galvanized inner tank, and B is a stainless steel inner tank)
Temperature control range
RT+5℃-250℃
Blower function

Studio size
25*25*25
35*35*35
45*35*45
55*45*55
60*50*75
80*80*100
100*100*100
Volume
16L
43L
70L
136L
225L
640L
1000L
Input voltage
220V
380V
Power
500W
800W
1500W
2000W
3000W
5000W
6000W
Partition gear position
3
4
5
6
7
9
9
Product size
35*41*52
45*51*62
55*51*72
65*61*82
70*66*102
90*96*127
110*116*127
Desktop drying oven
Model
202-0A
101-0A
101-00A
101-1A
101-2A
101-3A
101-4A
101-5A
202-0B
101-0B
101-00B
101-1B
101-2B
101-3B
101-4B
101-5B
(A is a galvanized inner tank, and B is a stainless steel inner tank)
Temperature control range
RT+5℃-250℃
Blower function

Studio size
25*25*25
25*25*25
35*35*35
45*35*45
55*45*55
60*50*758
80*80*100
100*100*100
Volume
16L
16L
43L
70L
136L
225L
640L
1000L
Input voltage
220V
380V
Power
500W
500W
800W
1500W
2000W
3000W
5000W
6000W
Partition gear position
3
3
4
5
6
7
9
9
Product size
49*36*39
49*36*39
59*46*49
69*46*59
79*56*70
84*61*91
104*91*116
124*111*116
High Capacity Stainless Steel Vertical Laboratory Drying Oven for Industrial Samples
High Capacity Stainless Steel Vertical Laboratory Drying Oven for Industrial Samples
High Capacity Stainless Steel Vertical Laboratory Drying Oven for Industrial Samples
High Capacity Stainless Steel Vertical Laboratory Drying Oven for Industrial Samples
High Capacity Stainless Steel Vertical Laboratory Drying Oven for Industrial Samples
High Capacity Stainless Steel Vertical Laboratory Drying Oven for Industrial Samples
FAQ

1. General Info
Q1: What types?
Two main types: vertical (uses floor - to - ceiling space for large - volume drying) and benchtop (saves bench space, fit for compact labs). Both have various sizes and support customization.
Q2: Customizable?
Yes. Aspects: inner tank (galvanized/stainless - steel); electrical specs (220V/380V); chamber size (16L–1000L, adjustable); optional feature tweaks (evaluated case - by - case).
2. Tech Specs
Q3: Temp range?
Controls from RT + 5℃ to 250℃, extreme limit 300℃. Suits diverse samples.
Q4: Temp accuracy?
Vertical: ±0.1℃ (for precision tasks like pharma R&D).
Benchtop: ±1℃ (good for general lab drying, e.g., glassware).
Q5: Power?
Spans 500W–6000W. Small 16L units start at 500W; large 1000L vertical reach 6000W. Higher power for bigger chambers.
Q6: Timer?
Sets 1min–9999min cycles, flexible for short/long drying.
3. Operation
Q7: Blower system?
Built - in blower circulates heated air for rapid, uniform heating, reducing warm - up time and hot/cold spots.
Q8: Monitor drying?
Yes, via double - pane glass windows to view samples without opening (preserves temp/humidity).
Q9: Shelves?
Adjustable (2 shelves, 3–9 gears). Fits diverse sample sizes; optimizes chamber space.
Q10: Exhaust holes?
Control airflow to manage humidity—open for fast moisture removal, restrict for slow drying.
4. App & Safety
Q11: Usable samples?
Versatile: herbs (10℃–100℃), food (70℃–170℃), glassware (100℃–170℃), instruments, industrial parts (up to 300℃).
Q12: Heat - sensitive?
Yes. Low temp (RT + 5℃) and uniform heating minimize risks. Adjust temp as needed.
Q13: Volatile samples?
Ensure lab ventilation; use exhaust holes. Check chemical - dryer compatibility. Wear PPE; ventilate before opening.
5. Maintenance & Purchase
Q14: Maintenance?
Clean regularly; inspect/replace worn seals; lubricate parts; calibrate sensors annually.
Q15: Safety?
Over - temp protection: Shuts off heating if needed.
Door safety: Secures during op; some block opening at high temps.
Electrical safety: Insulated/grounded.
Q16: Choose model?
Space: Vertical (floor) vs Benchtop (bench).
Volume: Vertical for large batches, Benchtop for smaller loads.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier